Product Features
FLUIDMATIC D3 is a high-performance automatic transmission fluid (ATF) designed to meet and exceed the requirements of a wide range of automotive manufacturers. It provides robust protection and enhances the reliability of automatic transmissions and hydraulic systems.
Manufacturer Approvals:
- ZF TE-ML 04D/14A
- MAN 339 Type V1/Z1
- Voith H55.6335.xx
- Volvo 97341
- Mercedes-Benz Trucks: DTFR 13C170 (236.9)
- DANA-OHTM-ATF (Approval ID 23C-0005)
- ALLISON C4 (TES-228)
- Ford Mercon
- GM Dexron IIIG / IIIH
- Volvo 97340
- Bosch TE ML 09
- GM TASA
- Dexron IID
- MAN 339 Typ L1/L2
- Mercedes-Benz: MB 236.2, MB 236.5, MB 236.6, MB 236.7, MB 236.8, MB 236.10
- Mercedes-Benz Trucks: DTFR 13C120 (236.2), DTFR 13C140 (236.7), DTFR 13C150 (236.8)
- Volvo 97337, 97335, 97325
- ZF TE-ML 05L, 11, 21L
FLUIDMATIC D3 incorporates advanced technology to reduce maintenance costs and ensure fewer interruptions. It offers robust and consistent protection for parts under various conditions, enhancing reliability and performance.
Applications:
- Heavy-duty and passenger car applications
- Automatic transmissions and hydraulic systems requiring GM DEXRON ®III ATF
- Outstanding Thermal Stability: High antioxidant and detergent levels provide superior thermal stability.
- Excellent Friction Properties: Ensures controlled slip for friction components, resulting in smooth gear shifting and clutch action.
- Precise and Smooth Shifting: Enables accurate and smooth automatic shifting, even at low speeds.
- Low Temperature Fluidity: Prevents surge or sudden overload of circuits in very cold weather.
- High Performance: Offers high anti-wear, anti-corrosion, and anti-foam properties.
- Always refer to the vehicle's maintenance guide before use.
- Follow the manufacturer's recommendations for oil changes.
- Store the product at temperatures below 60°C, away from sunlight, intense cold, and extreme temperature fluctuations.
- If stored outside, lay drums horizontally to prevent water contamination and preserve the label.
Test | Units | Test Method | Result |
Density at 15°C | kg/m3 | ISO 3675 | 843.5 |
Kinematic viscosity at 40°C | mm2 /s | ISO 3104 | 34.95 |
Kinematic viscosity at 100°C | mm2 /s | ISO 3104 | 7.373 |
Viscosity index | - | ISO 2909 | 186 |
Pour point | °C | ISO 3016 | -45 |
Flash Point | °C | ISO 2592 | 198 |